8. REPLACING THE BATTERY PACK
As sson as the autonomy of the instrument becomes unsufficient, the battery pack should
be changed.(Lifespan about 4 to 6 years)
1. Purchase a battery pack from your TRIMOS distributor.
2. Switch off the instrument.
3. Place the instrument in an horizontal position onto a table. (steady)
4. Unscrew the base plate. (5 screws)
5. Disconnect the battery pack (A)
6. Connect the new battery pack and refit the base plate. Take care not to damage
Any connecting cables.
7. Charge the new battery pack ~15 heures.
Battery pack
Code number
151-331.009